K1100
K1100 & RC1000 setup guides
Install the K1100 auto-off sensor, pair the RC1000 universal remote, and configure each device for your room.
K1100 · Auto-off sensor installation
Teach the sensor the AC OFF command and choose the timer before mounting. For bedrooms, use 60 or 90 minutes and position the sensor directly above the bed on the ceiling.
2 × 1.5V AAA · not included
5 meter radius
6 meters
Watch the full installation flow
This vertical setup guide walks through battery placement, remote learning, timer selection, and ceiling placement before mounting.
Insert the batteries
Insert two AAA batteries according to the battery (+) and (-) poles shown inside the device. Batteries are not included in the package.
Turn on your air conditioner
Use your existing air conditioner remote controller to turn the AC on before recording the OFF command.
Hold RECORD for 3 seconds
Press the Klisens RECORD button for 3 seconds. The LED will turn on, meaning Klisens is ready to learn the remote signal.
Teach the OFF command
While the LED is on, point your AC remote toward the Klisens receiver and press the remote controller's OFF button.
Test the signal
Turn Klisens toward the air conditioner and short press the RECORD button. Each press should turn the air conditioner off. It should not turn the AC on.
Set the timer
Short-press TIME to cycle through 15 / 30 / 60 / 90 minutes. Bedrooms require at least 60 minutes: select 60 or 90, never 15 or 30.
Mount on the ceiling directly above the bed
In bedrooms, mount K1100 on the ceiling directly above the bed so the sensing area covers small movements during sleep. Keep the sensing area clear, point the infrared transmitter toward the AC, fasten securely and repeat the OFF-signal test from this final position.
RC1000 · Pairing and temperature limits
Use the English videos below or follow the steps in the RC1000 manual. Pair the remote with the AC before setting temperature limits.
Pair the remote and unlock settings
Hold SET and TIME OFF together for three seconds to unlock the settings. Point the remote toward the AC, find a responding brand code using SET and TEMP + / TEMP −, press OK to save, then test the controls. Codes vary by AC; 165 is only the example in the video.
Set temperature limits and protect settings
Select heating mode and hold SET + F.HEAT for three seconds to set the maximum. In cooling mode, hold SET + TEMP − to set the minimum. Adjust each limit and confirm with OK. Finish by holding SET + TIME OFF for three seconds to lock the settings.
The videos demonstrate a 26°C heating maximum and a 22°C cooling minimum. Choose limits appropriate for your room. The remote may display a value beyond the limit while the AC remains at the configured limit.
K1100 learns the AC OFF signal; RC1000 is paired to the AC using its brand code. If using both, pair and test RC1000 first, then teach K1100 the confirmed OFF command.